Product Details:
Compression ratio | 16.8 |
Genset Output | 62.5 / 50 ( KVA / KW ) |
Genset Model | GPW II-PII- 62.5 |
Bore And Stroke | 108 X 133mm |
Engine Type | TCAC |
Displacement | 3.66 L |
Rated RPM | 1500 |
Genset Rating | Prime Power |
Genset Manufacturer | Greaves Power |
Engine Model | 3G11TAG25 |
Product Details:
Brand | Greaves Power |
Maximum allowable back pressure | 7 |
Genset Outpu | 400 / 400 ( KVA / KW e) |
Class of Governing | Electronic/G3 |
Genset Model | GPW II-400 |
Compression ratio | 17 |
Over speed trip | 1650 RPM |
Displacement | 16.8 ltr |
Stroke Size | 135 mm |
Air cleaner type | 02 |
Bore Size | 115 mm |
Rated RPM | 1500 RPM |
Genset Rating | Prime Power |
Engine Model | 12V14TAG23 |
No of Cylinders | 12 / V- type |
Engine Type | TCAC |
Voltage | 380-440V |
Frequency | 50Hz |
Current @ 0.8PF (Amps) | 556.5 |
Type | 4 Pole , Rotating |
Exciter Type | Brushless (Permanent magnet optional) |
Leads: Quantity , type | 6, fixed. 12, re connectable(Optional) |
Voltage regulator | Solid State |
Insulation | Class H , |
Temperature rise | 125 Deg. C ( Class H) |
Bearing: Quantity , type | 1,Sealed |
Coupling | Flexible disc Closed Coupled |
Voltage regulation : No load to full load | 2 Phase sensing,±1% |
One step load acceptance | 100% of rating |
Unbalance load capability | 25% of rated current |
Product Details:
Genset Model | GPW II-PII-50 |
Engine Model | 3G11TAG25 |
Displacement | 3.66 L |
Rated RPM | 1500 |
Genset Rating | Prime Power |
Genset Output | 50 / 50 ( KVA / KW ) |
Engine Type | TCAC |
Genset Manufacturer | Greaves Power |
Compression ratio | 16.8 |
Bore And Stroke | 108 X 133mm |
Product Details:
Brand | Greaves Power |
Genset Model | GPW II-500 |
Displacement | 16.8 ltr |
Engine rating | 444 (604) |
Over speed trip | 1650 RPM |
Class of Governing | 02 |
Bore Size | 115 mm |
Engine Type | TCAC |
No of Cylinders | 12 / V- type |
Genset Rating | Prime Power |
Air cleaner type | Dry |
Maximum allowable back pressure | 7 kpa |
Genset Output | 500 / 400 ( KVA / KW e) |
Engine Model | 12V14TAG23 |
Stroke Size | 135 mm |
Alternator Specification: | |
Voltage | 380-440V |
Frequency | 50Hz |
Current @ 0.8PF (Amps) | 695.6 |
Type | 4 Pole , Rotating |
Exciter Type | Brushless (Permanent magnet optional) |
Leads: Quantity , type | 6, fixed. 12, re connectable(Optional) |
Voltage regulator | Solid State |
Insulation | Class H , |
Temperature rise | 125 Deg. C ( Class H) |
Bearing: Quantity , type | 1,Sealed |
Coupling | Flexible disc Closed Coupled |
Voltage regulation : No load to full load | 2 Phase sensing,±1% |
One step load acceptance | 100% of rating |
Unbalance load capability | 25% of rated current |
Product Details:
Brand | Greaves Power |
Genset Output | 200 / 160 ( KVA / KW ) |
No of Cylinders | 6 Inline |
Stroke Size | 133 mm |
Rated RPM | 1500 RPM |
Compression ratio | 16.8 |
Genset Rating | Prime Power |
Engine Model | 6G11TAG29 |
Class of Governing | Mechanical/G2 |
Air cleaner type | 01 |
Bore size | 108 mm |
Genset Model | GPW II-PII-200 |
Engine Type | TCAC |
Displacement | 7.31 ltr |
Maximum allowable back pressure | 5.5 kpa |
Engine rating | 178.8 (243.1) |
Alternator Specification | |
Voltage | 380-440V |
Frequency | 50Hz |
Current @ 0.8PF (Amps) | 278.2 |
Type | 4 Pole , Rotating |
Exciter Type | Brushless (Permanent magnet optional) |
Leads: Quantity , type | 6, fixed. 12, reconnectable(Optional) |
Voltage regulator | Solid State |
Insulation | Class H , |
Temperature rise | 125 Deg. C ( Class H) |
Bearing: Quantity , type | 1,Sealed |
Coupling | Flexible disc Closed Coupled |
Voltage regulation : No load to full load | 2 Phase sensing,±1% |
One step load acceptance | 100% of rating |
Unbalance load capability | 25% of rated current |
Product Details:
Brand | Greaves Power |
Genset Model | GPWII-PII-320 |
Displacement | 13.38 ltr |
Air cleaner type | 02 |
Genset Output | 320 / 256 (KVA / KWe) |
Engine rating | 284 (386) |
No of Cylinders | 8 / V- type |
Engine Type | TCAC |
Compression ratio | 16.8 |
Class of Governing | Mechanical/G3 |
Engine Model | D3V8TAG21 |
Bore Size | 128 mm |
Stroke | 130 mm |
Rated RPM | 1500 RPM |
Maximum allowable back pressure | 5.5+0.5 kpa |
Over speed trip | 1650 RPM |
Genset Rating | Prime Power |
Alternator Specification: | |
Voltage | 380-440V |
Frequency | 50Hz |
Current @ 0.8PF (Amps) | 445.2 |
Type | 4 Pole , Rotating |
Exciter Type | Brushless (Permanent magnet optional) |
Leads: Quantity , type | 6, fixed. 12, re connectable(Optional) |
Voltage regulator | Solid State |
Insulation | Class H , |
Temperature rise | 125 Deg. C ( Class H) |
Bearing: Quantity , type | 1,Sealed |
Coupling | Flexible disc Closed Coupled |
Voltage regulation : No load to full load | 2 Phase sensing,±1% |
One step load acceptance | 100% of rating |
Unbalance load capability | 25% of rated current |
Product Details:
Genset Rating | Prime Power |
Genset Output | 100 / 80 ( KVA / KW ) |
Bore And Stroke | 108 X 133mm |
Genset Manufacturer | Greaves Power |
Compression ratio | 16.8 |
Rated RPM | 1500 |
Genset Model | GPW II-PII-100 |
Engine Model | 4G11TAG25 |
Engine Type | TCAC |
Displacement | 4.87 L |
Product Details:
Engine Type | TCAC |
Bore And Stroke | 108 X 133mm |
Compression ratio | 16.8 |
Rated RPM | 1500 |
Genset Output | 125/ 100( KVA / KW ) |
Engine Model | 4G11TAG26 |
Displacement | 4.87 L |
Genset Manufacturer | Greaves Power |
Genset Rating | Prime Power |
Product Details:
Genset Model | GPW II-PII-82.5 |
Compression ratio | 16.8 |
Bore and Stroke | 108 X 133mm |
Genset Manufacturer | Greaves Power |
Rated RPM | 1500 |
Genset Rating | Prime Power |
Genset Output | 82.5 / 66 ( KVA / KW ) |
Engine Model | 3G11TAG26 |
Engine Type | TCAC |
Displacement | 3.66 L |
Product Details:
Engine Type | TCAC |
Engine Model | 3G11ITAG26 |
Displacement | 3.66 L |
Bore And Stroke | 108 X 133mm |
Rated RPM | 1500 |
Genset Output | 75 / 60 ( KVA / KW ) |
Genset Model | GPW II-PII-75 |
Genset Manufacturer | Greaves Power |
Compression | 16.8 |
Genset Rating | Prime Power |
Product Details:
Brand | Greaves Power |
Genset Rating | Prime Power |
Genset Output | 45 / 45 ( KVA / KW ) |
Genset Model | GPW II-PII-45 |
Engine Model | 3G11TAG25 |
Engine Type | TCAC |
Product Details:
Compression ratio | 17.5 |
Rated RPM | 1500 |
Genset Model | GPW II-40A |
Engine Model | G-40-II |
Genset Manufacturer | Greaves Power |
Engine Type | TCAC |
Displacement | 2.86 (L) |
Bore And Stroke | 91X110(mm) |
Genset Rating | Prime Power |
Genset Output | 40 / 32( KVA / KW ) |
Engine rating or Max Power at rated RPM | 42.8 (58) |
Voltage | 380-440V |
Frequency | 50Hz |
Current | 130/41.7 |
Type | 4 Pole , Rotating field |
Exciter Type | Brushless |
Leads Quantity , type | 6, fixed. |
12, reconnectable (Optional) | |
Voltage regulator | Solid State, volts/Hertz |
Insulation | Class H , |
Temperature rise | 125 Deg. C (Class H) |
Bearing: Quantity , type | 1,Sealed |
Coupling | Flexible disc, CLOSE COUPLED |
Voltage regulation : No load to full load | 2 Phase sensing,±1% |
One step load acceptance | 100% of rating |
100% of rating | 25% of rated current |
Product Details:
Brand | Greaves Power |
Genset Rating | Prime Power |
Over speed trip | 1650 RPM |
Engine Type | TCAC |
Air cleaner type | 01 |
No of Cylinders | 6 Inline |
Bore Size | 128 mm |
Rated RPM | 1650 RPM |
Compression ratio | 16.8 |
Displacement | 10.03 ltr |
Engine Model | D3V6TAG21 |
Stroke Size | 130 mm |
Genset Model | GPW II-PII-250 |
Engine rating | 227 (309) RPM |
Genset Output | 250 / 200 Kva/kw |
Alternator Specification: | |
Voltage | 380-440V |
Frequency | 50Hz |
Current @ 0.8PF (Amps) | 347.8 |
Type | 4 Pole , Rotating |
Exciter Type | Brushless (Permanent magnet optional) |
Leads: Quantity , type | 6, fixed. 12, reconnectable (Optional) |
Voltage regulator | Solid State |
Insulation | Class H , |
Temperature rise | 125 Deg. C ( Class H) |
Bearing: Quantity , type | 1,Sealed |
Coupling | Flexible disc Closed Coupled |
Voltage regulation : No load to full load | 2 Phase sensing,±1% |
One step load acceptance | 100% of rating |
Unbalance load capability | 25% of rated current |
Product Details:
Brand | Greaves Power |
Engine Type | TCAC |
Over speed trip | 1650 RPM |
Engine rating | 178.8 (243.1) RPM |
Stroke size | 133 mm |
Air cleaner type | 01 |
Genset Model | GPW II-PII-160 |
Bore size | 108 mm |
Displacement | 7.31 ltr |
Genset Rating | Prime Power |
Genset Output | 160 KVA |
Engine Model | 6G11TAG29 |
Compression ratio | 16.8 |
Maximum allowable back pressure | 5.5 kpa |
No of Cylinders | 6 Inline |
Class of Governing | Mechanical/G2 |
Alternator Specification | |
Voltage | 380-440V |
Frequency | 50Hz |
Current @ 0.8PF (Amps) | 222.6 |
Type | 4 Pole , Rotating |
Exciter Type | Brushless (Permanent magnet optional) |
Leads: Quantity , type | 6, fixed. 12, re connectable(Optional) |
Voltage regulator | Solid State |
Insulation | Class H , |
Temperature rise | 125 Deg. C ( Class H) |
Bearing: Quantity , type | 1,Sealed |
Coupling | Flexible disc Closed Coupled |
Voltage regulation : No load to full load | 2 Phase sensing,±1% |
One step load acceptance | 100% of rating |
Unbalance load capability | 25% of rated current |